Limitor®- PTD Back-up Fuses, with Controlled Power Dissipation
Mersen HV fuse-links have been used for reliable protection in high-voltage switchgear and controlgear and high-voltage systems for decades. Limitor®-PTD HV fuse-links are back-up fuses as defined in the standards: IEC 60282-1 and VDE 0670 T402 and dedicated to protect transformers in combination with air or gas insulated switchgear against the thermal and dynamic effects of short-circuit currents. To guarantee high quality, Mersen uses the best materials: fuse-elements are in pure silver, caps are in copper coated with silver and bodies are in ceramic. Limitor®-PTD HV fuse-links are perfectly designed to be used in combination with HV switchgear. Siemens and Ormazabal recommend Limitor®-PTD HV fuses to be used in their gas-insulated switchgear.
Mersen HV fuse-links have been used for reliable protection in high-voltage switchgear and controlgear and high-voltage systems for decades. Limitor®-PTD HV fuse-links are back-up fuses as defined in the standards: IEC 60282-1 and VDE 0670 T402 and dedicated to protect transformers in combination with air or gas insulated switchgear against the thermal and dynamic effects of short-circuit currents. To guarantee high quality, Mersen uses the best materials: fuse-elements are in pure silver, caps are in copper coated with silver and bodies are in ceramic. Limitor®-PTD HV fuse-links are perfectly designed to be used in combination with HV switchgear. Siemens and Ormazabal recommend Limitor®-PTD HV fuses to be used in their gas-insulated switchgear.
Product data sheets
Charts
Compliance
- COM-REACH-declaration-0054-45DB-Limitor-fuses-Medium-Voltagepdf - 369.29 KB 
Key features & benefits
- High breaking capacity 
- High current limitation 
- Low switching voltage 
- Medium striker 80N/30mm 
- CPD striker: controlled power dissipation 
- Indoor and outdoor applications 
- Quick breaking 
- Non-ageing 
- Energy efficiency 
- New cap design for a better compatibility with all types of clips 
- and easier assembly 
- Coordination with IEC 60787, IEC 62271-105, IEC/TR 62655 
- and VDE 0671-105:2003-12 
Applications
- HV Transformer protection 
| Voltage Range | 3 ... 36 kV | 
| Amperage Range | 6.3 ... 160 A | 
| Reach Compliant | Yes | 
Reference Finder
Scroll
| Item number | Ampere rating | Fuse size | Clearing I2t At Rated Voltage | Indication System | Product weight | 
|---|---|---|---|---|---|
| A1000270 - 45DB120V63PTD See product | 63A | d=65mm L=292mm | 63kA²s | Yes | 2.2kg | 
| A1000293 - 45DB360V50PTD See product | 50A | d=88mm L=537mm | 40kA²s | Yes | 6.5kg | 
| B1000271 - 45DB120V80PTD See product | 80A | d=65mm L=292mm | 87kA²s | Yes | 2.2kg | 
| C1000272 - 45DB120V100PTD See product | 100A | d=65mm L=292mm | 140kA²s | Yes | 2.2kg | 
| D1000273 - 45DB120V125PTD See product | 125A | d=88mm L=292mm | 430kA²s | Yes | 3.8kg | 
| E1000274 - 45DB120V160PTD See product | 160A | d=88mm L=292mm | 670kA²s | Yes | 3.8kg | 
| F1000275 - 45DB240V6,3PTD See product | 6.3A | d=56mm L=442mm | 0.8kA²s | Yes | 2.4kg | 
| G1000276 - 45DB240V10PTD See product | 10A | d=56mm L=442mm | 2kA²s | Yes | 2.4kg | 
| H1000277 - 45DB240V16PTD See product | 16A | d=56mm L=442mm | 2.3kA²s | Yes | 2.4kg | 
| J1000278 - 45DB240V20PTD See product | 20A | d=56mm L=442mm | 3.9kA²s | Yes | 2.4kg | 