A6D-R - Class RK1 - Time-Delay
Amp-Trap 2000® time-delay A6D-R fuses provide IEC Type 2 "no damage" protection to existing mains, feeders, and branch circuits serving motor and non-motor loads. A6D-R fuses will open fast enough under extreme fault conditions for maximum short circuit protection to prevent damage to motor starters, switches, and other circuit components, yet also provide the time-delay needed for motor in-rush currents. A6D-R fuses can be used to replace older 600V Class H, K or RK5 fuses already installed in the field.
Amp-Trap 2000® time-delay A6D-R fuses provide IEC Type 2 "no damage" protection to existing mains, feeders, and branch circuits serving motor and non-motor loads. A6D-R fuses will open fast enough under extreme fault conditions for maximum short circuit protection to prevent damage to motor starters, switches, and other circuit components, yet also provide the time-delay needed for motor in-rush currents. A6D-R fuses can be used to replace older 600V Class H, K or RK5 fuses already installed in the field.
Product data sheets
- DS-A2D-R-A6D-R-Class-RK1-Time-Delay-Mersenpdf - 244.12 KB 
Compliance
- COM-RoHS-RS000039-A6D-R-Mersenpdf - 142.04 KB 
Key features & benefits
- Non-indicating or Solid state SmartSpot visual blown fuse indicator 
- Time-delay for motor starting and transformer inrush currents without nuisance opening 
- 600VAC & 600VDC dual rated 
- 300kA interrupting rating - self-certified, UL witnessed tests 
- Extremely current-limiting for low peak let-thru current 
- Recommended for Arc Flash energy reduction 
- Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs” 
- Rejection-style design prevents replacement errors (when used with recommended fuse blocks) 
- High-visibility orange label gives instant brand recognition 
- Reduced inventory by taking the place of class RK5, K, and H fuses 
- Metal-embossed date and catalog number for easier traceability and lasting identification 
- Fiberglass body provides dimensional stability in harsh industrial settings 
Applications
- Motors 
- Safety switches 
- Transformers 
- Branch circuit protection 
- Disconnects 
- Control panels 
- All general-purpose circuits 
| Frequency (Hz) | 50/60 Hz | 
| Amperage Range | 1/10 to 600 A | 
| Fuse Class | Class RK1 | 
| Speed/Characteristic | Time Delay | 
| UL Category Code | JDDZ | 
| CSA File Number | Class 1422-02 Guide 012636_0 | 
| Reach Compliant | Yes | 
| Max Operating Temp. | 80 °C | 
| Max Storage Temp. | 80 °C | 
| Min Storage Temp. | -25 °C | 
| Harmonized System | 853610 | 
| UL File Number | File E2137 | 
Reference Finder
Scroll
| Item number | Ampere rating | Fuse size | Clearing I2t At Rated Voltage | Indication System | Product weight | 
|---|---|---|---|---|---|
| A6D7R See product | 7A | - | - | No | 0.0662kg | 
| A6D8/10R See product | 0.8A | - | - | No | 0.0662kg | 
| A6D80R See product | 80A | - | - | Yes | 0.2803kg | 
| A6D80RN See product | 80A | - | - | No | 0.2803kg | 
| A6D8R See product | 8A | - | - | Yes | 0.0662kg | 
| A6D8RN See product | 8A | - | - | No | 0.0662kg | 
| A6D90R See product | 90A | - | - | Yes | 0.2803kg | 
| A6D90RN See product | 90A | - | - | No | 0.2803kg | 
| A6D9R See product | 9A | - | - | Yes | 0.0662kg | 
| A6D9RN See product | 9A | - | - | No | 0.0662kg | 
 
  