Fusible EVpack MEV100A, 1000 VDC maxi., L/R - 1 ms, 8 - 300 A, fusible cylindrique
EVpack-fuse line-up belongs to Mersen’s DC Over-Current protection (O.C.P.) portfolio specifically developed to address on-board electric and hybrid vehicles applications. EVpack-fuse provides the ultimate protection by offering reliable clearing of DC fault currents in challenging environments and complies with the high-quality requirements of the automotive industry. The MEV100C has specifically engineered and tested to provide best-in-class protection performance for auxiliary circuits: Up to 1000VDC, Current rating (In)= 5 to 30A, Interrupting Rating (IR) = 50kA,L/R ≤1ms, Minimum Breaking Capacity (MBC) = 2xIn for a perfect matching with cable protection.
EVpack-fuse line-up belongs to Mersen’s DC Over-Current protection (O.C.P.) portfolio specifically developed to address on-board electric and hybrid vehicles applications. EVpack-fuse provides the ultimate protection by offering reliable clearing of DC fault currents in challenging environments and complies with the high-quality requirements of the automotive industry. The MEV100C has specifically engineered and tested to provide best-in-class protection performance for auxiliary circuits: Up to 1000VDC, Current rating (In)= 5 to 30A, Interrupting Rating (IR) = 50kA,L/R ≤1ms, Minimum Breaking Capacity (MBC) = 2xIn for a perfect matching with cable protection.
Fiche produits
- DS-EVpack-fuse-MEV100-1000VDC-EN
pdf - 789.92 Ko
 
Brochures et Flyers
- BR-Fuses-and-Overcurrent-Protection-Devices-Brochure
pdf - 13.74 Mo
 - Mersen-Solutions-for-EV-HEV-e-Mobility-EN
pdf - 5.21 Mo
 - FLY-Solutions-for-E-Mobility-Mersen
pdf - 1.19 Mo
 
Applications produits
- AN-E-Mobility-Overcurrent-Protection-Guide-Mersen
pdf - 851.11 Ko
 
Compliance
- COM-REACH-RE000113-MEV100A-Mersen
pdf - 280.24 Ko
 - COM-CE-CE00014-MEV100A
pdf - 215.15 Ko
 
Caractéristiques et avantages
Design for DC applications
Low watt losses
High cycling performance
Full coverage of battery module voltage and current
Ultra compact size
Current Ratings (In): 8 to 300A
Interrupting Rating (IR): 20kA @ 1,000 VDC, L/R ≤1ms
Self Certified IR = 100kA, 1000VDC, L/R ≤ 3.7ms (UL Recognition Pending)
Applications
EV/HEV
Battery pack protection
Battery Disconnect Unit (BDU)
Battery Management System (BMS)
Battery Junction Box for auxiliaries
On-board charger
| Amperage Range | 50…200 A | 
| Conformité CE | Oui | 
| Conforme à REACH | Oui | 
| Température maximale de fonctionnement | 125 °C | 
| Température de fonctionnement minimale | -40 °C | 
Les références de cette gamme
Scroll
| Numéro d'article | Courant assigné | Taille du fusible | I2t total de coupure à tension nominale | Système d'indication | Poids du produit | 
|---|---|---|---|---|---|
| 
               MEV100A100-4 Voir le produit 
             | 
                      100A | - | - | Non | 0.117kg | 
| 
               MEV100A100-4Y Voir le produit 
             | 
                      100A | - | - | Non | 0.12kg | 
| 
               MEV100A125-4 Voir le produit 
             | 
                      125A | - | - | Non | 0.192kg | 
| 
               MEV100A125-4Y Voir le produit 
             | 
                      125A | - | - | Non | 0.19kg | 
| 
               MEV100A150-4 Voir le produit 
             | 
                      150A | - | - | Non | 0.192kg | 
| 
               MEV100A150-4Y Voir le produit 
             | 
                      150A | - | - | Non | 0.19kg | 
| 
               MEV100A175-4 Voir le produit 
             | 
                      175A | - | - | Non | 0.192kg | 
| 
               MEV100A175-4Y Voir le produit 
             | 
                      175A | - | - | Non | 0.19kg | 
| 
               MEV100A200-4 Voir le produit 
             | 
                      200A | - | - | Non | 0.192kg | 
| 
               MEV100A200-4Y Voir le produit 
             | 
                      200A | - | - | Non | 0.19kg |