A1023155 - 1.003.140
NH fuse-switch disconnector MULTIVERT® Size 00 160A 1x3-Pole switching Bus bar system 60mm Clamp Strap / Screw bottom terminal FM ready
MULTIVERT® NH vertical fuse switch disconnectors meet all functions of NH fuse switch disconnectors. They are designed for installation on to bus bars in triple pole arrangements. MULTIVERT® 160A 60mm triple pole switching are for installation on to 60 mm bus bar systems. MULTIVERT® 160A are designed for NH fuse-links in accordance with IEC/EN 60269-2, VDE 0636-2, size 00: 160A. The system is a modular system, that allows the installation of individual components. MULTIVERT® offer the user the possibility of fast and easy installation as well as a high degree of protection during installation and maintenance.
NH fuse-switch disconnector MULTIVERT® Size 00 160A 1x3-Pole switching Bus bar system 60mm Clamp Strap / Screw bottom terminal FM ready
MULTIVERT® NH vertical fuse switch disconnectors meet all functions of NH fuse switch disconnectors. They are designed for installation on to bus bars in triple pole arrangements. MULTIVERT® 160A 60mm triple pole switching are for installation on to 60 mm bus bar systems. MULTIVERT® 160A are designed for NH fuse-links in accordance with IEC/EN 60269-2, VDE 0636-2, size 00: 160A. The system is a modular system, that allows the installation of individual components. MULTIVERT® offer the user the possibility of fast and easy installation as well as a high degree of protection during installation and maintenance.
Datasheets
Compliances
| Item number | A1023155 |
| Catalogue No | 1.003.140 |
| Description | NH fuse-switch disconnector MULTIVERT® Size 00 160A 1x3-Pole switching Bus bar system 60mm Clamp Strap / Screw bottom terminal FM ready |
| EAN/UPC Code | 9008567006429 |
| Frequency (Hz) | 50 ... 60 Hz |
| Rated voltage AC IEC | 690 V |
| Ampere Rating | 160 A |
| Utilization Category | AC 23 B @ Ue = AC 400 V; Ie = 160 A AC 22 B @ Ue = AC 500 V; Ie = 160 A AC 22 B @ Ue = AC 690 V; Ie = 100 A DC 21 B @ Ue = DC 220 V; Ie = 160 A DC 21 B @ Ue = DC 440 V; Ie = 100 A |
| Switchability | 1x3-pole switching |
| ROHS Compliant | Yes |
| AC or DC | AC |
| Short Circuit Current Rating (SCCR) | 120kA@Ue = AC 400 V; Ie = 160 A / 120kA@Ue = AC 500 V; Ie = 160 A / 50kA@Ue = AC 690 V; Ie = 100 A |
| Fuse Size | 00 |
| Design Details | Clamp Strap / Screw bottom terminal |
| Number of Poles | 3-Pole |
| Degree of Pollution | 3 |
| Rated Impulse Withstand Voltage | 8 kV |
| Rated Insulation Voltage | 1000 V |
| Rated SC Withstand | 4.5 kA / 1 s |
| Max Power dissipation of Fuse Links Pn | 12 W |
| Max Power dissipation of Solid Links Pn | 1.2 W |
| Power Dissipation by Ith without Fuse-Links | 18 W |
| Power Dissipation by Ith without Solid Links | 44 W |
| Rated short circuit making capacity with solid links Icm | 4.5 kA |
| Installation Mounting | Bus bar system 60 mm |
| Product Width | 50 mm |
| Product Length | 116 mm |
| Product Height | 406 mm |
| Sell Pack Quantity | 1 EA |
| Sell Pack Weight | 1.5 kg |
| Sell Pack Width | 125 mm |
| Sell Pack Length | 413 mm |
| Sell Pack Height | 51 mm |
| Product group | IEC Fuse Switch Disconnectors |
| Product Weight | 1.5 kg |
| Conventional Free Air thermal Current With Fuse-Links Ith | 160 A |
| Conventional Free Air thermal Current - Solid Links | 250 A |